HIC.SOAP Standard Edition
Overview:
The Holladay IOL Consultant & Surgical Outcomes Assessment is a "smart" data base program that
automatically minimizes a surgeon's prediction error for intraocular lens power calculations
every time postoperative results are entered. The program can handle an unlimited number of IOL's,
surgeons and patients.
IOL power calculations comparing the current third generation formulas (Holladay2, Holladay 1,
Hoffer Q and the SRK/T) are easily performed. Features for calculating surgically-induced
astigmatism and back-calculating values to determine the source of refractive surprises only
require clicking one button.
Competitive Features of Holladay IOL Consultant Program
STANDARD EDITION
(Windows '98, NT, '00, XP, or M)
IOL Calculations:
-
PhakicEyes
- Standard Cataract IOL calculation
- Primary Piggy-back IOL calculation
- AC, PC & ILC IOL calculation high minus phakic IOL
-
Aphakic Eyes
- Secondary IOL calculation from axial length
- Secondary IOL calculation from Aphakic Refraction
-
Pseudophakic Eyes
- Secondary Piggy-Back IOL calculation for residual refractive error
- Lens Exchange IOL calculation
-
Axial Length Measurement Corrections
- Correction of axial length measurement in pseudophakia for any lens material and lens power
- Correction of axial length measurement in aphakia
-
Multiple Formulas
- Includes Holladay 2, Holladay 1, SRK/T , Hoffer Q and Holladay Refraction
-
IOL Database
- All lenses currently manufactured are in the database with lens properties
- Program allows addition of new lenses not currently in data base
-
Unlimited Number of Surgeons and Active Lenses
-
Alternate K-values for Post Keratorefractive Surgery
- Calculates alternate K-value from refractive data, contact lens method and topography
-
Lens constant personalization
- Automatically calculates personalized lens constant for all formulas with comparitve formula results
- Allows the surgeon to choose any of the formulas for IOL calculations
-
Outcomes Analysis
- Histogram of BCVA & UCVA results
-
Surgically Induced Refractive Change (SIRC)
- Calculates SIRC from refractive data & K-readings
-
Back-Calculations
- Allows back-calculations for all preoperative input values to determine cause of refractive surprise
-
Additional Features
- Compensates for in-the-bag versus in-the-sulcus lens placement
- Determines the optimal add in the IOL for Bifocal IOL calculations
- Determines the optimal toricity in the IOL for Toric IOL calculations
- Performs IOL calculation for Silicone in the vitreous cavity
- Predicts average myopic shift with time in pediatric patient
- Allows choice of visual acuity notation: feet, metric or decimal
- All data is backed-up to disk, for protection if computer failure
- Views other databases to compare or review data from another surgeon or clinic
System Requirements for STANDARD EDITION:
The program runs on any IBM compatible computer running Windows '98, '00, NT, XP, or M.
Recommend minimum resolution of 600 x 800 pixels for optimum viewing.